New Transmission Storage Compression Station Print E-mail

SCFM DELIVERS RESULTS
  
 
 
OUTCOME:
•  Saved customer over $2M in equipment costs
•  Saved
customer 10% on Hp 
    
The Customer Situation:
•   There were two units required for a total of 11,000 hp
•   Compressor Manufacturer’s solution was 7” stroke 6 throw reciprocating compressor at 900 rpm

Challenges:
•  
Envelope of operation was extensive and complicated
•  
Multiple services on each compressor operation

The SCFM Solution:
   Used a 1200 rpm unit with a 5.5” stroke to lower the upfront costs of the equipment for our customer
•   Piston speed would remain roughly the same
•   
Used pipeline cylinders in the storage performance by using two stages, which gained efficiency in both storage and transmission

 

The Results:

•   Reduced major equipment costs alone approximately $2,000,000 over the industry standard unit
•   
Got the performance done in a much smaller footprint unit.  7” stroke vs. 5.5” stroke machine 
•   The estimated reduction  in construction costs was 15%
•   
The hp required averaged 10% less than the Compressor manufacturer’s recommended performance for the same flow rate.  Cost savings at $0.04 per KWH would be roughly $300,000 per
year for the life of the equipment.